Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 48(8): 1681-1690, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35577660

RESUMO

Ultrasound-induced cavitation is currently under investigation for several potential applications in cancer treatment. Among these, the use of low-intensity ultrasound, coupled with the systemic administration of various cavitation nuclei, has been found to enhance the delivery of co-administered therapeutics into solid tumors. Effective pharmacological treatment of solid tumors is often hampered, among various factors, by the limited diffusion of drugs from the bloodstream into the neoplastic mass and through it, and SonoTran holds the potential to tackle this clinical limitation by increasing the amount of drug and its distribution within the ultrasound-targeted tumor tissue. Here we use a clinically ready system (SonoTran Platform) composed of a dedicated ultrasound device (SonoTran System) capable of instigating, detecting and displaying cavitation events in real time by passive acoustic mapping and associated cavitation nuclei (SonoTran Particles), to instigate cavitation in target tissues and illustrate its performance and safety in a large-animal model. This study found that cavitation can be safely triggered and mapped at different tissue depths and in different organs. No adverse effects were associated with infusion of SonoTran Particles, and ultrasound-induced cavitation caused no tissue damage in clinically targetable organs (e.g., liver) for up to 1 h. These data provide evidence of cavitation initiation and monitoring performance of the SonoTran System and the safety of controlled cavitation in a large-animal model using a clinic-ready platform technology.


Assuntos
Acústica , Neoplasias , Animais , Modelos Animais de Doenças , Neoplasias/terapia , Ultrassonografia
2.
Artigo em Inglês | MEDLINE | ID: mdl-32845836

RESUMO

Passive acoustic mapping (PAM) techniques have been developed for the purposes of detecting, localizing, and quantifying cavitation activity during therapeutic ultrasound procedures. Implementation with conventional diagnostic ultrasound arrays has allowed planar mapping of bubble acoustic emissions to be overlaid with B-mode anatomical images, with a variety of beamforming approaches providing enhanced resolution at the cost of extended computation times. However, no passive signal processing techniques implemented to date have overcome the fundamental physical limitation of the conventional diagnostic array aperture that results in point spread functions with axial/lateral beamwidth ratios of nearly an order of magnitude. To mitigate this problem, the use of a pair of orthogonally oriented diagnostic arrays was recently proposed, with potential benefits arising from the substantially expanded range of observation angles. This article presents experiments and simulations intended to demonstrate the performance and limitations of the dual-array system concept. The key finding of this study is that source pair resolution of better than 1 mm is now possible in both dimensions of the imaging plane using a pair of 7.5-MHz center frequency conventional arrays at a distance of 7.6cm. With an eye toward accelerating computations for real-time applications, channel count reductions of up to a factor of eight induce negligible performance losses. Modest sensitivities to sound speed and relative array position uncertainties were identified, but if these can be kept on the order of 1% and 1 mm, respectively, then the proposed methods offer the potential for a step improvement in cavitation monitoring capability.


Assuntos
Acústica , Terapia por Ultrassom , Processamento de Sinais Assistido por Computador , Som , Ultrassonografia
3.
IEEE Trans Med Imaging ; 37(12): 2582-2592, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29994701

RESUMO

Sources of nonlinear acoustic emissions, particularly those associated with cavitation activity, play a key role in the safety and efficacy of current and emerging therapeutic ultrasound applications, such as oncological drug delivery, blood-brain barrier opening, and histotripsy. Passive acoustic mapping (PAM) is the first technique to enable real-time and non-invasive imaging of cavitation activity during therapeutic ultrasound exposure, through the recording and passive beamforming of broadband acoustic emissions using an array of ultrasound detectors. Initial limitations in PAM spatial resolution led to the adoption of optimal data-adaptive beamforming algorithms, such as the robust capon beamformer (RCB), that provide improved interference suppression and calibration error mitigation compared to non-adaptive beamformers. However, such approaches are restricted by the assumption that the recorded signals have a Gaussian distribution. To overcome this limitation and further improve the source resolvability of PAM, we propose a new beamforming approach termed robust beamforming by linear programming (RLPB). Along with the variance, this optimization-based method uses higher-order-statistics of the recorded signals, making no prior assumption on the statistical distribution of the acoustic signals. The RLPB is found via numerical simulations to improve resolvability over time exposure acoustics and RCB. In vitro experimentation yielded improved resolvability with respect to the source-to-array distance on the order of 22% axially and 13% transversely relative to RCB, whilst successfully accounting for array calibration errors. The improved resolution and decreased dependence on accurate calibration of RLPB is expected to facilitate the clinical translation of PAM for diagnostic, including super-resolution, and therapeutic ultrasound applications.


Assuntos
Algoritmos , Terapia por Ultrassom/métodos , Ultrassonografia/métodos , Simulação por Computador , Desenho de Equipamento , Processamento de Sinais Assistido por Computador , Transdutores , Terapia por Ultrassom/instrumentação , Ultrassonografia/instrumentação
4.
Int J Nanomedicine ; 13: 337-349, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29391793

RESUMO

The treatment of cancer using nanomedicines is limited by the poor penetration of these potentially powerful agents into and throughout solid tumors. Externally controlled mechanical stimuli, such as the generation of cavitation-induced microstreaming using ultrasound (US), can provide a means of improving nanomedicine delivery. Notably, it has been demonstrated that by focusing, monitoring and controlling the US exposure, delivery can be achieved without damage to surrounding tissue or vasculature. However, there is a risk that such stimuli may disrupt the structure and thereby diminish the activity of the delivered drugs, especially complex antibody and viral-based nanomedicines. In this study, we characterize the impact of cavitation on four different agents, doxorubicin (Dox), cetuximab, adenovirus (Ad) and vaccinia virus (VV), representing a scale of sophistication from a simple small-molecule drug to complex biological agents. To achieve tight regulation of the level and duration of cavitation exposure, a "cavitation test rig" was designed and built. The activity of each agent was assessed with and without exposure to a defined cavitation regime which has previously been shown to provide effective and safe delivery of agents to tumors in preclinical studies. The fluorescence profile of Dox remained unchanged after exposure to cavitation, and the efficacy of this drug in killing a cancer cell line remained the same. Similarly, the ability of cetuximab to bind its epidermal growth factor receptor target was not diminished following exposure to cavitation. The encoding of the reporter gene luciferase within the Ad and VV constructs tested here allowed the infectivity of these viruses to be easily quantified. Exposure to cavitation did not impact on the activity of either virus. These data provide compelling evidence that the US parameters used to safely and successfully delivery nanomedicines to tumors in preclinical models do not detrimentally impact on the structure or activity of these nanomedicines.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Ultrassom/métodos , Adenoviridae , Linhagem Celular , Cetuximab/administração & dosagem , Cetuximab/química , Doxorrubicina/administração & dosagem , Vetores Genéticos/administração & dosagem , Vetores Genéticos/química , Humanos , Nanomedicina/métodos , Vaccinia virus
5.
Phys Med Biol ; 63(6): 065008, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29459494

RESUMO

Previous work has demonstrated that passive acoustic imaging may be used alongside MRI for monitoring of focused ultrasound therapy. However, past implementations have generally made use of either linear arrays originally designed for diagnostic imaging or custom narrowband arrays specific to in-house therapeutic transducer designs, neither of which is fully compatible with clinical MR-guided focused ultrasound (MRgFUS) devices. Here we have designed an array which is suitable for use within an FDA-approved MR-guided transcranial focused ultrasound device, within the bore of a 3 Tesla clinical MRI scanner. The array is constructed from 5 × 0.4 mm piezoceramic disc elements arranged in pseudorandom fashion on a low-profile laser-cut acrylic frame designed to fit between the therapeutic elements of a 230 kHz InSightec ExAblate 4000 transducer. By exploiting thickness and radial resonance modes of the piezo discs the array is capable of both B-mode imaging at 5 MHz for skull localization, as well as passive reception at the second harmonic of the therapy array for detection of cavitation and 3D passive acoustic imaging. In active mode, the array was able to perform B-mode imaging of a human skull, showing the outer skull surface with good qualitative agreement with MR imaging. Extension to 3D showed the array was able to locate the skull within ±2 mm/2° of reference points derived from MRI, which could potentially allow registration of a patient to the therapy system without the expense of real-time MRI. In passive mode, the array was able to resolve a point source in 3D within a ±10 mm region about each axis from the focus, detect cavitation (SNR ~ 12 dB) at burst lengths from 10 cycles to continuous wave, and produce 3D acoustic maps in a flow phantom. Finally, the array was used to detect and map cavitation associated with microbubble activity in the brain in nonhuman primates.


Assuntos
Acústica , Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Crânio/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Humanos , Macaca mulatta , Masculino , Microbolhas
6.
Small ; 11(39): 5305-14, 2015 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-26296985

RESUMO

Ultrasound-induced bubble activity (cavitation) has been recently shown to actively transport and improve the distribution of therapeutic agents in tumors. However, existing cavitation-promoting agents are micron-sized and cannot sustain cavitation activity over prolonged time periods because they are rapidly destroyed upon ultrasound exposure. A novel ultrasound-responsive single-cavity polymeric nanoparticle (nanocup) capable of trapping and stabilizing gas against dissolution in the bloodstream is reported. Upon ultrasound exposure at frequencies and intensities achievable with existing diagnostic and therapeutic systems, nanocups initiate and sustain readily detectable cavitation activity for at least four times longer than existing microbubble constructs in an in vivo tumor model. As a proof-of-concept of their ability to enhance the delivery of unmodified therapeutics, intravenously injected nanocups are also found to improve the distribution of a freely circulating IgG mouse antibody when the tumor is exposed to ultrasound. Quantification of the delivery distance and concentration of both the nanocups and coadministered model therapeutic in an in vitro flow phantom shows that the ultrasound-propelled nanocups travel further than the model therapeutic, which is itself delivered to hundreds of microns from the vessel wall. Thus nanocups offer considerable potential for enhanced drug delivery and treatment monitoring in oncological and other biomedical applications.


Assuntos
Antineoplásicos/administração & dosagem , Preparações de Ação Retardada/química , Eletroporação/métodos , Nanocápsulas/química , Neoplasias Experimentais/tratamento farmacológico , Sonicação/métodos , Animais , Antineoplásicos/química , Sobrevivência Celular/efeitos dos fármacos , Preparações de Ação Retardada/efeitos da radiação , Relação Dose-Resposta à Radiação , Feminino , Camundongos , Camundongos Endogâmicos BALB C , Movimento (Física) , Nanocápsulas/administração & dosagem , Nanocápsulas/efeitos da radiação , Neoplasias Experimentais/complicações , Neoplasias Experimentais/patologia , Ondas Ultrassônicas
7.
Artigo em Inglês | MEDLINE | ID: mdl-23143581

RESUMO

A new 2-D hydrophone array for ultrasound therapy monitoring is presented, along with a novel algorithm for passive acoustic mapping using a sparse weighted aperture. The array is constructed using existing polyvinylidene fluoride (PVDF) ultrasound sensor technology, and is utilized for its broadband characteristics and its high receive sensitivity. For most 2-D arrays, high-resolution imagery is desired, which requires a large aperture at the cost of a large number of elements. The proposed array's geometry is sparse, with elements only on the boundary of the rectangular aperture. The missing information from the interior is filled in using linear imaging techniques. After receiving acoustic emissions during ultrasound therapy, this algorithm applies an apodization to the sparse aperture to limit side lobes and then reconstructs acoustic activity with high spatiotemporal resolution. Experiments show verification of the theoretical point spread function, and cavitation maps in agar phantoms correspond closely to predicted areas, showing the validity of the array and methodology.


Assuntos
Acústica/instrumentação , Terapia por Ultrassom/instrumentação , Terapia por Ultrassom/métodos , Ágar/química , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Imagens de Fantasmas , Polivinil/química
8.
J Acoust Soc Am ; 130(5): 3489-97, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22088024

RESUMO

The spatial resolution of cavitation maps generated from passive recordings of cavitation emissions is compromised by the bandlimited nature of the recordings. Deconvolution based on the assumption that cavitation consists of a sparse series of discrete events allows the recovery of frequency components that are not only outside the frequency band of the receivers, but may also have been attenuated by the medium before being detectable. In the current work, two sparse deconvolution techniques, matching pursuit and basis pursuit, were applied to simulated and experimental cavitation recordings before they were beamformed to provide passive maps of cavitation activity. Matching pursuit was shown to reduce the maximal diameter of the point spread function by almost a third, at the cost of greater susceptibility to inter-source interference. In contrast, although basis pursuit causes an almost 20% increase in the maximal diameter of the point spread function, its application to experimental data appears to enhance the ability of passive mapping to resolve multiple sources.


Assuntos
Modelos Teóricos , Processamento de Sinais Assistido por Computador , Ultrassom , Simulação por Computador , Gases , Movimento (Física) , Análise Numérica Assistida por Computador , Pressão , Som , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...